Low Voltage PVC and XLPE armoured and non-armoured cables are manufactured to British, IEC and customized standards under strict quality control procedures. These cables have a voltage rating of 600/1000V.

PVC Insulated Power Cables are manufactured with plain annealed stranded copper. Multicores are laid together and protected with an inner sheath of PVC, armoured with steel round wires and single core cables are armoured with aluminium wires and finally protected by an outer layer of PVC sheath. Non-armoured cables are without the additional inner sheath and armouring. PVC sheathing of all cables are UV protected and are Flame Retardant.

Inner and outer PVC sheathing materials where the halogen acid evolved is less than 15% of total mass when heated at 800ºC are also available upon request.

XLPE Insulated Power Cables are manufactured with plain annealed stranded copper. Multicores are laid together and protected with an inner sheath of PVC, armoured with steel round wires and single core cables are armoured with aluminium wires and finally protected by an outer layer of PVC sheath.

Range : 1C x 10mm2 to 1C x 1000mm2 , 2C x 1.5mm2 to 5C x 500mm2 (For armoured)

Range : 1C x 1.5mm2 to 1C x 1000mm2 , 2C x 1.5mm2 to 5C x 500mm2 (For non-armoured)

PVC Insulated Standards / Specifications : BS 6346, IEC 60502-1, IEC 60332-3 and other standards as per customer’s request

XLPE Insulated Standards / Specifications : BS 5467, IEC 60502-1, IEC 60332-3 and other standards as per customer’s request

Fire safety is clearly one of the top priorities in infrastructure safety for modern buildings of any category. A fire once spread out of control, can quickly cause extensive damage to property and ultimately human lives. More often than not, it is the speed of fire spreading, the existence of corrosive halogen gases by burning chlorine containing materials and the inhalation of smoke that make safe escape from a fire difficult and dangerous. Pancab’s FRT (LSZH) Flame Retardant, Low Smoke Zero Halogen Armoured and Non-armoured cables are available to ease such fears.

Range : 1C x 10mm2 to 1C x 1000mm2 , 2C x 1.5mm2 to 5C x 500mm2 (For armoured)

Range : 1C x 1.5mm2 to 1C x 1000mm2 , 2C x 1.5mm2 to 5C x 500mm2 (For non-armoured)

FRT Standards / Specifications : BS 6724, IEC 60502-1, IEC 60332-3, IEC 60754, IEC 61034 and other standards as per customer’s request.

SPECIFICATION

Type

Description

Max. Operation Temperature

No. of Cores

Cross Section

mm2

Cu(Al)/XLPE/PVC

Cu(Al) conductor

XLPE insulation

PVC sheath

90℃

1

1.5~1000

2~5

1.5~500

Cu(Al)/XLPE/SWA/PVC

Cu(Al) conductor

XLPE insulation

Steel wire armored

PVC sheath

90℃

1

1.5~1000

2~5

1.5~500

Cu(Al)/PVC/PVC

Cu(Al) conductor

XLPE insulation

PVC sheath

90℃

1

1.5~1000

2~5

1.5~500

Cu(Al)/PVC/SWA/PVC

Cu(Al) conductor

XLPE insulation

Steel wire armored

PVC sheath

90℃

1

1.5~1000

2~5

1.5~500